Table 3 ROC curve analyses of second-trimester cervical elastography, cervical length and endocervical canal width for the diagnosis of cervical insufficiency

From: Changes in cervical elastography, cervical length and endocervical canal width after cerclage for cervical insufficiency: an observational ultrasound study

 

Cut-off value

Sensitivity

Specificity

AUC

95% CI

P value

Anterior cervical lip strain rate

0.14%

0.88

0.55

0.76

0.66–0.85

< 0.001*

Posterior cervical lip strain rate

0.09%

0.79

0.58

0.69

0.59–0.79

0.002*

Cervical length

37.4 mm

0.66

0.71

0.67

0.57–0.78

0.005*

Endocervical canal width

   

0.58

0.46–0.71

0.186

  1. ROC, receiver operating characteristic; AUC, area under the curve; CI, confidence interval
  2. *P < 0.05 was considered statistically significant